Compendial testing for the raw materials your product is built on.

ACTA tests APIs, excipients, and raw materials against their USP, EP, BP, CP, or JP monograph for identity, strength, quality, and purity. Send us the material and the monograph, and a chemist and/or microbiologist scopes the panel. The same lab tests the finished product it becomes.

MONOGRAPH TEST PANELcGMP
IdentificationIR <197>Conforms
AssayHPLC <621>Meets
Related substances<621>Meets
Loss on drying<731>Meets
Residue on ignition<281>Meets
Elemental impurities<232> / <233>Meets
Residual solvents<467>Meets
PHARMACOPEIA USP-NFDELIVERABLE cGMP COA
FDA Registered
DEA Licensed I to V
cGMP Compliant
Analyzing Since 1990
RAW MATERIAL TESTING

What ACTA tests on a raw material

ACTA performs compendial monograph testing on incoming raw materials, active pharmaceutical ingredients (APIs), and excipients. For a named article, ACTA follows the USP and NF, EP, BP, CP, or JP monograph, a method you have already validated, or a method ACTA develops and validates in house.

A typical panel covers identity by infrared <197> and the general and chemical identification tests <191>, <193>, <201>, and <202>; assay by HPLC or titration per <621>; related substances and organic impurities by HPLC; loss on drying <731> and water by Karl Fischer <921>; residue on ignition <281>; elemental impurities <232> and <233> by ICP-MS, with the older <231> heavy metals test where a monograph still cites it; and residual solvents <467> by headspace GC.

You receive a cGMP Certificate of Analysis (COA) that states each attribute, its result, the specification, and the pharmacopeia and edition applied. Because ACTA also tests finished products, one lab can carry a material from the incoming raw lot through the product it becomes.

Related USP Chapters
<191> Identification<193><197> IR Identification<201><202><281> Residue on Ignition<467> Residual Solvents<621> Chromatography<731> Loss on Drying<741> Melting Range<841> Specific Gravity<921> Water Determination<231> Heavy Metals<232> Elemental Impurities Limits<233> Elemental Impurities Procedures<1226> Verification of Compendial Procedures
THE METHOD

Compendial or not, the method has to be proven

A monograph gives you the method, but a method still has to be shown to work in the lab that runs it, if FDA GMP compliance is needed. USP <1226> Verification of Compendial Procedures confirms that a compendial method performs for your specific article, on ACTA's instruments and analysts. It is a targeted check, not a full revalidation. It looks at the attributes that matter for the material, such as specificity, accuracy, precision, and a system suitability check.

When a method is non-compendial, when you use an alternative to the monograph procedure, or when you change the compendial method, that method needs full validation to USP <1225> and ICH Q2, and it has to be shown equivalent to the compendial method.

ACTA develops, validates, verifies, and transfers methods in house when requested by our clients. The same lab that tests your raw material owns the method behind every number on the COA.

FROM NAMED ARTICLE TO CERTIFICATE OF ANALYSISflow
NAMED ARTICLEThe named article and its monograph.ARTICLEmaterial + monographFit the method to the article.METHOD FITverify or validateConfirm identity.IDENTITYIR <197>Run the purity and assay panel.PURITY + ASSAYassay + purityReport against the monograph.COAper monograph

From the named article to the COA: fit the method, confirm identity, run the purity and assay panel, and report against the monograph. Hover any stage to see what it does.

WHY A SMALLER LAB

Big labs won't take one incoming lot. We will.

The large labs route a single raw material into a queue that can take a month to start. ACTA takes the one material, scopes the monograph panel with a chemist, and follows up. Many of our largest accounts started as one small test. And because ACTA also runs the finished product, one lab can carry your material from the incoming raw lot through the product it becomes.

1990Analyzing since
13,000 sq ftTwo buildings, Foothill Ranch CA
DEA Schedules I to VFDA-registered, DEA-licensed, cGMP
Pharma + deviceFDA-regulated clients only
HOW WE RUN IT

Four steps, and a chemist runs each one.

ScopeA chemist reviews your material, its monograph, and which pharmacopeia and edition apply.
MethodVerify the compendial method per <1226>, or develop and validate a method per <1225> for your article.
AnalysisIdentity, assay, related substances, and the residue and physical tests, under cGMP.
ReportA cGMP Certificate of Analysis (COA), and we follow up on your results.
REGISTRATIONS & COMPLIANCE

Registrations, scope, and quality systems

FDA Establishment RegistrationRegistered · FEI No. 1000125694
DEA LicenseSchedules I to V · License No. RA0256239
Quality SystemcGMP, 21 CFR Parts 210, 211, and 820
Data Integrity21 CFR Part 11 Computer Systems coupled with Good Documentation Practices
CompendiaUSP, BP, JP, and EP methods
FDA Inspection History14 inspections (NDA, ANDA, and general cGMP) · Most recent Sept. 2026, 2 minor observations
Certificate of AnalysisConcise 1 to 2 page cGMP Certificate of Analysis (COA)
Established1990 · 13,000 sq ft, two buildings · Foothill Ranch, CA
ScopePharmaceutical and medical device, FDA-regulated only
Typical Quote Turnaround1 working day

Send us your raw material and its monograph.

A specific material against a specific monograph. We will scope the panel, get you a quote, and a chemist will follow up. FDA-registered, DEA-licensed, cGMP since 1990.
Request a Quote
949-595-0641
info@actalabs.com