Residual solvents to USP <467>, screened, confirmed, and quantified.

Static headspace gas chromatography with flame ionization detection at a cGMP, FDA-registered, DEA-licensed laboratory. Class 1, 2, and 3 solvents to USP <467> and ICH Q3C on drug substances, drug products, and excipients. GC-MS capabilities to confirm identification of compound if desired. Send a specific material and a chemist scopes it directly.

Static headspace GC-FID · USP <467>cGMP
acetonitriletoluenebenzene 2 ppm
PROCEDURE A screenCOLUMN USP G43OUTPUT ppm vs limit
FDA Registered
DEA Licensed I to V
cGMP Compliant
Analyzing Since 1990
WHAT IT IS

Residual solvents testing, USP <467> and ICH Q3C

Residual solvents are volatile organic chemicals used or produced in the manufacture of a drug substance, excipient, or drug product, and not fully removed by processing. USP General Chapter <467> is the compendial method for controlling them, harmonized with ICH Q3C, which classifies solvents by toxicity and sets limits.

The technique is static headspace gas chromatography. The sample is sealed in a heated vial so the volatile solvents partition into the gas above it, and only that headspace is injected, which keeps the non volatile matrix out of the instrument. Flame ionization detection quantifies the separated solvents. ACTA uses GC-MS to support identification if desired by the client.

ACTA follows USP, BP, JP, and EP methods, or develops and validates a method when a solvent is not addressed by the compendial procedure. One nuance worth knowing: ICH Q3C applies to new drug products, while USP <467> applies the same limits to new and existing products.

Standards applied
USP <467>ICH Q3CBP / JP / EPICH Q2 validation
SOLVENT CLASSES

Three classes, set by toxicity and permitted daily exposure

ICH Q3C sorts solvents into three classes. The permitted daily exposure, or PDE, is the amount of a solvent a patient can receive per day, and it converts to a concentration limit in the product based on the daily dose.

Class 1
avoid

Solvents with unacceptable toxicity, such as benzene and carbon tetrachloride. Known or suspected human carcinogens and environmental hazards, controlled to the lowest levels.

Class 2
limit

Solvents to be limited, such as methanol, acetonitrile, and methylene chloride, each controlled to a permitted daily exposure and a concentration limit.

Class 3
low toxicity

Solvents with low toxic potential, such as ethanol and acetone, generally acceptable up to 50 mg per day without further justification.

Class 1 benzene
2 ppm
Concentration limit, to be avoided
Class 2 acetonitrile
410 ppm
Concentration limit, Option 1
Class 3
5000 ppm
0.5 percent, generally acceptable
HOW WE RUN IT

The USP <467> three procedure structure

USP <467> runs as a screen, a confirmation, and a quantitation. A material that passes the screen is done. Only a solvent that appears over its limit moves forward.

Procedure A

Identification and limit

Headspace GC-FID on a USP G43 column screens Class 1 and Class 2 solvents against their limits. A material that meets every limit here is reported and complete.

Procedure B

Confirmation

Any solvent that appears to exceed its limit in Procedure A is confirmed on a USP G16 column, an orthogonal separation that rules out a coeluting interference.

Procedure C

Quantitation

A quantitative determination for any solvent that does not meet its limit under Procedures A and B, reporting a result in ppm per solvent with chromatograms.

For a Class 1 solvent at trace level, or any solvent whose identity is in question, ACTA can confirm the identification by GC-MS. The mass spectrum is a structural fingerprint matched against reference libraries, stronger evidence of identity than retention time alone. For quantitation by gas chromatography generally, see GC analysis and testing.

WHAT YOU CAN SEND

Screening, quantitation, and method development

Most work is a compendial screen against the USP <467> and ICH Q3C class limits, with a pass or limit report as the deliverable. When a result is over a limit, Procedure C returns a quantified ppm value per solvent.

When a process uses a solvent that is not addressed by the compendial procedure, ACTA develops and validates a product specific method to ICH Q2, so the solvent you actually use is the one that gets measured.

Residual solvents scope
Compendial solvent screenUSP <467> / Q3C
Quantitation over limitppm per solvent
Class 1 trace confirmationGC-MS identity
Product specific methoddevelop + validate
Substance, product, excipientand raw materials
WHY A SMALLER LAB

Big labs won't take a project your size. We will.

As the big labs consolidate, they have stopped taking projects that are not large enough, and just getting into their queue can take a month. ACTA is FDA-registered, DEA-licensed, and cGMP, and small enough to actually respond and follow up. Many of our largest accounts started as one residual solvents test.

1990Analyzing since
13,000 sq ftTwo buildings, Foothill Ranch CA
DEA Schedules I to VFDA-registered, DEA-licensed, cGMP
Pharma + deviceFDA-regulated clients only
REGISTRATIONS & COMPLIANCE

Run under a cGMP quality system

FDA Establishment RegistrationRegistered
DEA LicenseSchedules I to V
Quality SystemcGMP, 21 CFR Parts 210, 211, and 820
Data Integrity21 CFR Part 11 with Good Documentation Practices
CompendiaUSP, BP, JP, and EP methods
ScopePharmaceutical and medical device, FDA-regulated only
See the full quality and compliance record →

Need a solvent screened or quantified?

Send us the material and the question. We will scope it, quote it, and a scientist will follow up. FDA-registered, DEA-licensed, cGMP since 1990.
Request a Quote